CLD-250
|
CLD-400
|
CLD-600
|
CLD-1200
|
CLD-1800
| |
---|---|---|---|---|---|
Intern volume/ Doors |
250 / 1
|
400 / 1
|
600 / 1
|
1200 / 2
|
1800 /
3
|
Extern dimensions
(D×W×H m)
|
0,50X0,65
H 1,61
|
0,60X0,61
H 1,76
|
0,81×0,72
H 2,16
|
0,81×1,55
H 2,16
|
0,81×2,10
H 2,16
|
Temperature range |
+3
|
to +15°C |
±2,5°
|
C | |
Insulation width mm |
35
|
35
|
50
|
50
|
50
|
Backup refriger. (DX) |
--------
|
--------
|
--------
|
Optionally
|
Optionally |
Door(s)
Glass /
with insulat
|
YES/ NO
|
YES/ NO
|
YES/ YES
|
YES /YES
|
YES/ YES
|
Power Plugs |
1
|
2
|
3
|
6
|
6
|
Power supply |
220-
|
240VAC
|
1pH/50Hz
|
CDR brings many models in each cabinet size. Standard features and available optional accessories, designed to meet the rigid
requirements of different laboratories, make them an ideal solution for chromatography or cold storage of sensitive material. Capacities
range from 250 to 1800 liters.
For maximum protection of sensitive products CDR produce secure refrigerators coded \DX. These models
have two full size identical refrige-ration plants. A special made control system interchange every 4 hours the active plant so it
keeps both of them always <<ready>> to work. When one of the plant fail the control system isolate it and make active
the healthy on.
SLIM AND DURABLE CONSTRUCTION
Cabinet construction features galvanized steel (optionally stainless steel) and foam in place polyurethane insulation that binds inner and outer walls in to a single unit for greater strength and thinner wall construction for more working capacity. Final surfaces are covered with antitoxic materialfor hygienic purposes. Standard modes have adjustable epoxy coated wire shelves.Optionally half size shelves for chroma-tography purposes and stainless steel pull-out drawers are available.
Pull out drawers have ball-bearing mechanism which delivers 100% pullout capacity. Self closing door with magnetic gaskets secure
the temperature isolation. The slim design and optional sliding shelves allows for an ergonomic easy-reach retrieval of your product.Models coded \G have double pane glass door(s) that allows observation internally and saves energy consumption. All units have access
port holes for connecting instruments with wires and tubes without sacrificing in cooling efficiency.
ELECTRONIC THERMOSTAT
WITH AUTO DEFROST
All standard models feature a user selectable/easy to read digital control with automatic defrost and a self contained refrigeration system mounted on top of the unit and balanced to maintain 4 C.
The air circulation system provides even air flow and temperature control throughout the chamber.